Bosch Indego 400 Connect: Boundary wire / perimeter signal fault

Boundary / signal · Evidence: manufacturer-support + diagnostic-procedure

What this fault means

Indego cannot use the perimeter installation correctly.

Safety: Stop the mower and follow the manufacturer safety instructions before physical inspection.

Step-by-step checks

  1. Check station power and both perimeter connections.
  2. Inspect recent garden work and known wire joints for damage.
  3. Use a temporary small loop when possible to separate loop damage from mower/base electronics.
  4. Check whether the error occurs everywhere or only one section.
  5. Only replace electronics after a known-good test loop still fails.

Evidence source: Manufacturer/support reference

Evidence checked 2026-08-25. Diagnostic procedures are labelled separately from manufacturer-exact error instructions.