Gardena smart SILENO sense 400: No loop signal
Boundary / signal · Evidence: manufacturer-exact
What this fault means
The mower cannot detect a valid boundary loop.
Safety: Stop the mower and follow the manufacturer safety instructions before physical inspection.
Step-by-step checks
- Read the charging-station LED first.
- If the LED flashes blue, inspect the boundary connection, wire damage and the guide-to-boundary connector.
- If the LED is off, diagnose station power before digging up wire.
- If the LED flashes green or otherwise indicates a different mode, follow the exact SILENO model support path rather than assuming a break.
- Use a temporary short test loop to separate installation faults from mower/station electronics when appropriate.
Evidence source: Manufacturer/support reference
Evidence checked 2026-08-25. Diagnostic procedures are labelled separately from manufacturer-exact error instructions.
Did one of these checks actually fix the mower?
Confirmed repair outcomes improve MowerFixAI for the next owner and help separate common symptoms from real component failures.
Record the confirmed fix Run full diagnosis