← MowerFixAI

STIGA A 4: Cannot find / reach charging station

Return / positioning · Evidence: diagnostic-procedure

What this fault means

The robot cannot complete its autonomous return to its known charging position.

Safety: Stop the mower and follow the manufacturer safety instructions before physical inspection.

Step-by-step checks

  1. Check that the station is powered and unobstructed.
  2. Verify current GPS/RTK position is valid before changing the map.
  3. Inspect the approach path for new physical obstacles.
  4. Clean charging contacts so a successful docking event is recognised.
  5. If the robot reaches the station but fails to dock, treat alignment/contacts separately from navigation.

Evidence source: Manufacturer/support reference

Evidence checked 2026-08-25. Diagnostic procedures are labelled separately from manufacturer-exact error instructions.

Did one of these checks actually fix the mower?

Confirmed repair outcomes improve MowerFixAI for the next owner and help separate common symptoms from real component failures.

Record the confirmed fix Run full diagnosis