Worx Landroid M700 Plus (WR167E): Outside working area

Boundary / polarity · Evidence: manufacturer-exact

What this fault means

The mower detects itself outside its wire-defined territory.

Safety: Stop the mower and follow the manufacturer safety instructions before physical inspection.

Step-by-step checks

  1. Turn power off and place the mower well inside the lawn.
  2. Confirm the base LED is green/normal.
  3. If the mower is inside but reports outside, reverse/check the boundary-wire ends at the station as specified by Worx.
  4. Inspect the loop for a cut or poor connection if the station LED is abnormal.
  5. Restart only after the installation state is normal.

Evidence source: Manufacturer/support reference

Evidence checked 2026-08-25. Diagnostic procedures are labelled separately from manufacturer-exact error instructions.

Did one of these checks actually fix the mower?

Confirmed repair outcomes improve MowerFixAI for the next owner and help separate common symptoms from real component failures.

Record the confirmed fix Run full diagnosis